Subject: Product Outage/Anomaly: Update #1: NOAA-19 anomaly on the This is a multi-part message in MIME format. --Boundary_(ID_qwTZOMHovWov0G1j510jfA) Content-type: text/plain; charset=utf-8; format=flowed Content-transfer-encoding: 8BIT *Update #1: *NOAA-19 MHS (Microwave Humidity Sounder) experienced an anomaly starting on 9 Oct 2017 (17/282) at ~0425 UTC. There were numerous alarms observed in real-time and it appeared that the MHS data was ‘stale’. EUMETSAT (European Organization for the Exploitation of Meteorological Satellites) has investigated and confirmed the MHS is OFF. There is currently not believed to be anything wrong with the MIU (MHS Interface Unit) and that the problem lies solely with the MHS. The MHS will be attempted to be powered by NOAA on Oct 13, 2017 and reconfigured the following week for science channel data. The root cause remains under investigation by NOAA/NASA/EUMETSAT Engineering. * * *Topic*: NOAA-19 anomaly on the MHS/MIU *Date/Time Issued: *October 12, 2017 2145Z* Product(s) or Data Impacted:* MHS Sounding Products *Impacts on Users and Significance: *MHS sounding products are severely impacted ** *Date/Time of the Initial Impact:* October 09, 2017 0425Z *Date/Time of Expected End:* TBD* * ** *Length of the Outage: *TBD *Details/Specifics of Change: * At approximately 0425 UTC, three temperatures on the NOAA-19 MHS have dropped significantly, one below it's red limit. The three temps that are cold are telemetered independent of instrument or MIU status. It is believed the MHS is safed and that the MIU is echoing the last packet it received prior to the MHS going safe. The anomaly is still being investigated. *Contact Information for Further Information:* ESPC Operations at ESPCOperations@noaa.gov at 301-817-3880 *Web Site(s) for applicable information:* N/A This message was sent by ESPC.Notification@noaa.gov. You have been sent this and other notifications because you have opted in to receive it. If for any reason, you wish to unsubscribe, please contact ESPC Help Desk at ESPCOperations@noaa.gov or (301) 817-3880. Please note: it make take up to two business days to process your unsubscribe request. ** --Boundary_(ID_qwTZOMHovWov0G1j510jfA) Content-type: text/html; charset=utf-8 Content-transfer-encoding: 8BIT

Update #1:  NOAA-19 MHS (Microwave Humidity Sounder) experienced an anomaly starting on 9 Oct 2017 (17/282) at ~0425 UTC.  There were numerous alarms observed in real-time and it appeared that the MHS data was ‘stale’. EUMETSAT (European Organization for the Exploitation of Meteorological Satellites) has investigated and confirmed the MHS is OFF.  There is currently not believed to be anything wrong with the MIU (MHS Interface Unit) and that the problem lies solely with the MHS. The MHS will be attempted to be powered by NOAA on Oct 13, 2017 and reconfigured the following week for science channel data.  The root cause remains under investigation by NOAA/NASA/EUMETSAT Engineering.  

Topic: NOAA-19 anomaly on the MHS/MIU

Date/Time Issued: October 12, 2017 2145Z

Product(s) or Data Impacted:
  MHS Sounding Products

Impacts on Users and Significance: MHS sounding products are severely impacted

Date/Time of the Initial Impact: October 09, 2017 0425Z

Date/Time of Expected End: TBD

Length of the Outage: TBD

Details/Specifics of Change:

At approximately 0425 UTC, three temperatures on the NOAA-19 MHS have dropped significantly, one below it's red limit. The three temps that are cold are telemetered independent of instrument or MIU status. It is believed the MHS is safed and that the MIU is echoing the last packet it received prior to the MHS going safe. The anomaly is still being investigated.

Contact Information for Further Information: ESPC Operations at ESPCOperations@noaa.gov at 301-817-3880

Web Site(s) for applicable information: N/A

This message was sent by ESPC.Notification@noaa.gov. You have been sent this and other notifications because you have opted in to receive it. If for any reason, you wish to unsubscribe, please contact ESPC Help Desk at ESPCOperations@noaa.gov or (301) 817-3880. Please note: it make take up to two business days to process your unsubscribe request.


--Boundary_(ID_qwTZOMHovWov0G1j510jfA)--