Subject: Product Outage/Anomaly: GOES-15 (GOES-West) Imager Calibration --e89a8ff1c4b8d6699f04bb9799f6 Content-Type: text/plain; charset=windows-1252 Content-Transfer-Encoding: quoted-printable Topic: GOES-15 (GOES-West) Imager Calibration issue for band 3 during March 12-16, 2012 Date/Time Issued: March 18, 2012 1225 UTC Product(s) or Data Impacted: GOES-15 (GOES-West) Imager. Date/Time of Initial Impact: March 12, 2012 2021 UTC Date/Time of End: March 16, 2012 2045 UTC Length of Affected Data: 4 days, March 12 (2045 UTC) to March 16 (2045 UTC), 2012 Details/Specifics of Change: Due to a database coefficient (IBBTR) error in the Sensor Processing Subsystem (SPS), there was a cold bias (of approximately 5%) in the GOES-15 imager band 3 (6.5 um) from March 12 (2045 UTC) to March 16 (2045 UTC), 2012. Other bands were affected (warm bias) but at smaller levels. GVAR Words 7019=967242 (found in Block 0) IBBTR BB temperature-to-target radiance conversion coefficients. An array of 56 elements, 4 elements for each of the 14 IR detectors. Impact: All GOES-15 Imager images during the time range, mostly the band 3 (6.5 um). GOES-15 Sounder was not affected. Contact Information for Further Information: ESPC Operations at ESPCOperations@noaa.gov at 301-817-3880 Web Site(s) for applicable information: See http://www.ssd.noaa.gov/PS/**SATS/messages.html for this and other satellite related messages. See http://www.osd.noaa.gov/GVAR_Downloads/gvar_downloads.html for more GVAR information. This message was sent to ESPC.Notification@noaa.gov. You have been sent this and other notifications because you have opted in to receive it. If for any reason, you wish to unsubscribe, please contact ESPC Help Desk at ESPCOperations@noaa.gov or (301) 817-3880. Please note: it make take up to two business days to process your unsubscribe request. --e89a8ff1c4b8d6699f04bb9799f6 Content-Type: text/html; charset=windows-1252 Content-Transfer-Encoding: quoted-printable Topic: GOES-15 (GOES-West) Imager Calibration issue for band 3 during= March 12-16, 2012

Date/Time Issued: =A0March 18, 2012 = =A01225 UTC

Product(s) or Data Impacted: GOES-15 (GOES-= West) Imager.

Date/Time of Initial Impact: =A0March 12, 2012 =A02021 UTC=

Date/Time of End: =A0March 16, 2012 =A02045 UTC
Length of Affected Data: 4 days, March 12 (2045 UTC) to March 16 (20= 45 UTC), 2012

Details/Specifics of Change: Due to a database coefficient (IBBTR= ) error in the Sensor Processing Subsystem (SPS), there was a cold bias (of= approximately 5%) in the GOES-15 imager band 3 (6.5 um) from March 12 (204= 5 UTC) to March 16 (2045 UTC), 2012. =A0Other bands were affected (warm bia= s) but at smaller levels. =A0GVAR Words 7019=967242 (found in = Block 0) IBBTR BB temperature-to-target radiance conversion coefficients. = =A0An array of 56 elements, 4 elements for each of the 14 IR detectors.

Impact: =A0All GOES-15 Imager images during the time ran= ge, mostly the band 3 (6.5 um). =A0GOES-15 Sounder was not aff= ected. =A0

Contact Information for Further Information: ESPC Operations at= =A0ESPCOperations@noaa.go= v=A0at=A0301-817-3880

Web Site(s) for applicable information:
See =A0http://www.ssd.noaa.gov/PS/SATS/messages.html=A0=A0for this and other satellite related = messages.
See =A0
http://www.osd.noaa.gov/GVAR_Downloads/gvar_downloads.html<= /a>=A0=A0for more=A0GVAR=A0information.=A0

This message was sent to=A0ESPC.Notification@noaa.gov. You have been sent this and other notifications because you have op= ted in to receive it. If for any reason, you wish to unsubscribe, please co= ntact ESPC Help Desk at=A0ESPCOperations@noaa.gov=A0or=A0(301) 817-3880. Please note: it make take up to two business days to process your u= nsubscribe request.